Optional GEC / Bonding Connection

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

If required by an AHJ, a dedicated grounding/bonding point is located on the left exterior side of the inverter. See Item (13) in the EI Inverter Overview section. This connection point may be used for a grounding electrode conductor or equipment bonding if using a metal mounting surface. This ground/bond is not required for operation of the inverter.

Use a crimping tool to crimp the O-type terminal (P) provided in the accessory bag to the bare copper ground/bonding conductor. Attach the O-type terminal to the ground hole using the safety-screw (M) provided in the accessory bag.

Figure 19 GEC/Bonding Connection